EasyManuals Logo

Polycom HDX Series Administrator's Guide

Polycom HDX Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
Administrator’s Guide for Polycom HDX Systems
C - 8
99 Information element
nonexistent or not
implemented
The equipment received a message that includes
information elements which were not recognized.
This is usually due to a D-channel error. If this
error occurs systematically, report it to your ISDN
service provider.
100 Invalid information
element contents
The equipment received a message that includes
invalid information in the information element. This
is usually due to a D-channel error.
101 Message not
compatible with call
state
The remote equipment received a message that
does not correspond to the current state of the
connection. This is usually due to a D-channel
error.
102 Recovery on timer
expiry
A time-out has triggered an error-handling
(recovery) procedure. This problem is typically
temporary.
111 Protocol error,
unspecified
An unspecified D-channel error when no other
standard cause applies.
127 Interworking,
unspecified
An event occurred within a network that does not
provide causes for the action that it takes. The
precise problem is unknown.
145 ISDN layer 1 and/or
2 link not
established
User needs to check cabling, ISDN adapter status
and network connections.
146 ISDN layer 3
connection to the
ISDN
switch/network
inactive
There is either a switch protocol error, or (in the
United States or Canada) a SPID assignment
problem.
255 ISDN command
processing error
The ISDN signaling code has encountered an
error processing an ISDN action. ISDN adapter
busy-wait and retry.
Code Cause Definition

Table of Contents

Other manuals for Polycom HDX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom HDX Series and is the answer not in the manual?

Polycom HDX Series Specifications

General IconGeneral
Network ProtocolsH.323, SIP
Video Resolution1080p (depending on model)
Audio TechnologyPolycom StereoSurround
Content SharingPeople+Content
MicrophoneIntegrated or external
Video StandardsH.264, H.263
Audio StandardsG.711, G.722, G.722.1, G.728
Data StandardsH.239
Network Interface10/100/1000 Ethernet
Video InputsHDMI, DVI-I
Video OutputsHDMI, DVI-I
Audio InputsHDMI, RCA
Audio OutputsRCA
Power ConsumptionVaries by model
Operating Temperature0°C to 40°C (32°F to 104°F)
Humidity10% to 90% non-condensing

Related product manuals