Administration and Utilities
Polycom, Inc. 136
15 Define the following parameters:
16 To specifically define valid terminals, de-select the Accept SNMP Packets from any Host check
box, and click Add.
The Accepted Host IP Address dialog opens.
17 Enter the IP Address of the Manager terminal from which valid queries may be sent to the MCU, and
click OK.
Field Description
Send Authentication
Trap
Select this check box to send a message to the SNMP Manager
when an unauthorized query is sent to the MCU. When cleared, no
indication will be sent to the SNMP Manager.
Versions
1 & 2
Accept Host Community
Name
Enter the string added to queries that are sent from the SNMP
Manager to indicate that they were sent from an authorized source.
Note: Queries sent with different strings are regarded as a violation of
security, and, if the Send Authentication Trap check box is selected,
an appropriate message is sent to the SNMP Manager.
Accept SNMP Packets
from all Host
Select this option if a query sent from any Manager terminal is valid.
When selected, the Accept SNMP Packets from These Hosts option
is disabled.
Accept SNMP Packets
from the following Hosts
Lists specific Manager terminals whose queries will be considered as
valid. This option is enabled when the Accept SNMP Packets from
any Host option is cleared.
User Name Enter a User Name of up to 48 characters
Default: Empty
Version3
Security Level Select a Security Level from the drop-down menu.
Range: No Auth, No Priv; Auth, No Priv; Auth, Priv
Default: Auth, Priv
Authentication Protocol Select the authentication protocol
Range: MD5, SHA
Default: MD5
These fields are
enabled if
Authentication
is selected in the
Security Level
field.
Authentication
Password
Enter an Authentication Password.
Range: 8 - 48 characters
Default: Empty
Privacy Protocol Select a Privacy Protocol.
Range: DES, AES
Default: DES
These fields are
enabled if
Privacy is
selected in the
Security Level
field.
Privacy Password Enter a Privacy Password.
Range: 8 - 48 characters
Default: Empty
Engine ID Enter an Engine ID to be used for both the Agent
and the Trap.
Default: Empty