Polycom, Inc. 283
Active Alarms
The following table describes the active alarms the RealPresence Collaboration Server may experience.
Active Alarms
Alarm Text Alarm Description
A matching activation key is required.
To cancel the upgrade process, reset
the Collaboration Server
The system upgrade requires that a valid activation key be entered. If
none is available, resetting the Collaboration Server will cancel the
upgrade and return the Collaboration Server to the previous version.
The card type in slot <n> is not
compatible with RMX version, card will
not be powered on
A Collaboration Server Appliance Edition was upgraded to versions 8.6,
yet it contains an MPMx media card(s) which is not supported.
The card is not powered on.
Note: Applicable to Collaboration Servers 2000/4000.
A new activation key was loaded.
Reset the system.
A new activation key was loaded: Reset the MCU.
A new version was installed. Reset the
system.
A new version was installed: Reset the MCU.
Alarm generated by a Central
Signaling component
A system alert was generated by a component of the Central Signaling.
Alarm generated by an internal
component
A system alert was generated by an internal system component.
Allocation mode was modified
Automatic reset is unavailable in Safe
Mode
The system switches to safe mode if many resets occur during startup. To
prevent additional resets, and allow the system to complete the startup
process the automatic system resets are blocked.
Backup of audit files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that audit files need to be backed up.
Backup of CDR files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that CDR files need to be backed up.
Backup of log files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default
setting when ULTRA_SECURE_MODE System Flag is set to YES) and a
Cyclic File reaches a file retention time or file storage capacity limit, the
user is alerted that log files need to be backed up.