Active Alarms
Polycom, Inc. 290
MPL startup failure. Management
Network configuration not received.
Management Network message was not received. Check the Switch
card.
Network interface is not configured.
New interface need to be chosen
Network traffic capture is on
New certificate for CS need
Collaboration Server reset to take
effect
No clock source The system could not use any of the connected ISDN-video spans as
clock source. Check the ISDN (audio/video) Settings.
Note: Applicable to Collaboration Servers 2000/4000/1800
No default ISDN/PSTN Network
Service defined in ISDN/PSTN
Network Services list
Set a default ISDN (audio/video) Network Service.
Note: Applicable to Collaboration Servers 2000/4000/1800
No default IVR Service in IVR Services
list
No default IVR Service in IVR Services list. Ensure that one conference
IVR Service and one EQ IVR Service are set as default.
No IP Network Services defined IP Network Service parameters missing. Configure the IP Network
Service.
No ISDN/PSTN Network Services
defined
No ISDN (audio/video) Network Services were defined or no default
ISDN (audio/video) Network was defined.
Note: Applicable to Collaboration Servers 2000/4000/1800
No LAN connection
No License for ISDN/PSTN. Please
activate the RTM ISDN card through
Polycom website
Configure the ISDN (audio/video) Network Service.
Note: Applicable to Collaboration Servers 2000/4000/1800
No response from Central Signaling No connection with central signaling.
No response from RTM ISDN card Note: Applicable to Collaboration Servers 2000/4000/1800
No RTM-LAN or RTM-ISDN installed.
One of these cards must be installed in
the RealPresence Collaboration
Server (RMX) 4000
Note: Applicable to Collaboration Servers 2000/4000/1800
No usable unit for audio controller No media card is installed, or the media card installed is not functioning.
Install the appropriate media card.
OCS Registration failed
Password expiration warning
Please install a newer version
Port configuration was modified