Appendix - Modular MCU
Polycom, Inc. 370
A specific conference
A specific participant in a conference
The resulting log files are stored in the Main MCU, under MMCU/Logger/Collector FS as follows:
CollectInfo_<begin date&time>-<end date&time>.tgz - A log file for the Main MCU.
A folder named Blades, for log files filtered from all the Soft Blades. Under this folder there are:
Folders named Translator.<ID>, for each of the Soft Blades log files.
A folder named Translator.777777, for log files filtered from the local Translators (i.e.
Translators residing on the Main MCU, such as for WebRTC).
Each of the filtered log files is limited to 100MB.
Furthermore, when a filter specifies a conference/participant, for which one of the involved Soft
Blades is inoperable, the user is notified that the returned logs are partial (for a conference), or cannot
be supplied (for a participant in the specified conference).
To filter logs according to conference and/or participants:
1 In the Collaboration Server main menu, select Administration > Tools > Information Collector.
2 Determine the time frame of the desired logs.
3 To filter the logs of a specific conference beginning within this time frame:
a Click Select Conference.
b Select the conference to use for the filter, and click OK.
The time frame you previously selected, is modified to that of the selected conference; for an ongoing
conference, the end time is determined to be the current time.
4 To filter the logs of a specific participant in the selected conference:
a Click Select Participants.
b Select the participant to use for the filter, and click OK.
5 Determine the location in which the filtered logs are stored, by entering it or via Browse.
6 Click Collect Information to generate the appropriate log files.
Error Handling
Should a failure occur at one of the Soft Blades - from best case scenario of the Collaboration Server
application level, down to the worst case scenario of the Soft Blade machine termination - all retrievable log
files are sent to the Main MCU, accompanied by a notification listing the files which could not be retrieved.
Modular MCU Upgrade Process
The modular MCU and its soft blades can be upgraded together with one upgrade software (*.bin for RMX
1800/2000/4000, *.upg for Virtual Edition) that also being used for non-modular MCU upgrade, all soft
blades will be upgraded automatically during the modular MCU reboot.
You can upgrade modular MCU in the same way of upgrading non-modular MCU, the only difference is that
upgrading modular-MCU may take extra 1 or 2 minutes. and you can monitor the soft blades upgrade status