64-92 PN-0908073 Rev. 11
PS 164-2
THE ART OF WELDING
Error code Possible causes What to do
62 - Power source was switched off after the last weld
- The selected program (XX) is not the same as the one
(YY) that was used to do the last weld
- Do a weld again
- Select the (YY) program and
print again a ticket with SY 29
switch
70 - No memory card in the SY 27 port
- Memory card is incorrectly introduced in the port
- Introduce a memory card
- Put out the card and introduce
71 - Memory card was put out too early when program was
saving.
- Start saving operation again
72 - 21700633 card was changed - Have all programs (from 0 to 15)
to run with BT 4 coder switch on
the control pendant
73 - No recorded program on the memory card
- Memory card is reverse introduced in the SY27 port
- Introduce a recorded memory
card
- Put out the card and introduce it
again rightly
74 - Withdraw of memory card before reading message or
print error
75*
*When reading
a memory card
- SY 30 key switch (50 A / 160 A) is not in the same
position as in creating the program
- Recorded program on the memory card is not suitable
with PS 164-2 power source
- Wrong position of S3/1 switch of 21700633 card
- Wrong position of S3/4 switch of 21700633 card
- Turn the switch and introduce
the program again
- Use a suitable program
- Place in "CLOSED" position
- Check
77 - Memo card full - Delete a program or use an
empty card

Table of Contents