INDEX
18
K6 K8 K10 K20 | SERVICE MANUAL
Supply an external 18V DC on connector J4 of the power
supply control board (KALSU) by means of the PSU AUX
VOLTAGE CABLE (Fig. 11)
Verify that current draw is as portrayed in the following
table:
If the current drawn is within range, apply an external Vdc
on the mains external plug by means of the K STD/HGT
DC MAINS CABLE.
Please take the precaution to slowly increase the voltage
from 0 Vdc to 50 Vdc whilst checking the current drawn
by the amplier. (The presence of the capacitors bank
may affect the speed with which the voltage will increase).
If no other damages other than the varistors burning have
occurred during the over-voltage, at around 50V DC the
current drawn should be slightly lower than 3 A. Thanks
to the PFC the amp should switch on.
Verify the voltage readings between the points highlighted
on (Fig. 12) in relation to the following table.
In case of negative outcome, discharge the capacitors
bank and check the power supply VBoost stage, and
refer to the table below when ordering the repair Kit.
1
2
3
VAUX
+Vdc-Vdc -Vdc
AUX SUPPLY
J4
MLX90P3
18Vdc 140mA
50Vdc
(Fig. 11)
(Fig. 12)
Model Kit
K STD
KT000807.R
K HGT KT000813.R
Model Kit
K STD
KT000806.R
K HGT
KT000812.R
Model Kit
K STD
KT000808.R
K HGT
KT000814.R
Amp Model Current Draw
K_STD 140 mA
K_HGT 165 mA
Amp Model VRails Voltage Readings
K_STD +/- 195 Vdc ± 10%
K_HGT +/- 220 Vdc ± 10%