Cleaning Solutions
Wipe down equipment with recommended cleaning solution. Use dry cloth to remove residue
solution.
l General: 1 oz. mild soap (Simple Green) to 30 oz. water.
l Console and PVS
1
: a diluted solution of one part 91% Isopropyl alcohol to one part
water.
CAUTION: Do not use acidic cleaners and do not spray directly onto the equipment
surfaces.
Electrical Requirements
Dedicated Branch Circuit
It is required that the treadmill be connected to and operated on a dedicated 20 amp AC
2
branch circuit. A Dedicated Branch Circuit is defined as a circuit fed by a single circuit breaker
feeding a single load, with a single non-shared neutral providing a return line. A treadmill oper-
ating from a non-dedicated branch circuit or a circuit breaker of less than 20 amps capacity will
not have the necessary power to operate normally under higher load conditions.
120 Vac Systems
120 VAC
3
distribution systems utilize a single pole circuit breaker (power lead) and a neutral
lead connected to a common neutral (ground) bar. The AC. safety ground (green wire) is con-
nected to a separate ground bar in the distribution system.
If it is determined that any of the above electrical conditions are in question, please consult with
a qualified electrician to make appropriate circuit changes.
CAUTION: The treadmill requires a 20-amp individual branch circuit grounded per
NEC (National Electric Code) guidelines or local region electric code.
IMPORTANT: If the AC circuit feeding a treadmill is found to be a non-dedicated
branch circuit or a circuit equipped with a capacity of less than 20 amps, the AC circuit
must be corrected before any reliable Troubleshooting can be performed. More
importantly, a non-dedicated branch circuit may constitute a safety hazard to the tread-
mill operator.
1
Personal Viewing System display.
2
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
3
voltage in an alternating current circuit
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 7
2 General Information
Cleaning Solutions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor GEN06 Series and is the answer not in the manual?

Precor GEN06 Series Specifications

General IconGeneral
BrandPrecor
ModelGEN06 Series
CategoryTreadmill
LanguageEnglish

Related product manuals