106 70284701
Section 8 Micro Display Control Troubleshooting - Door open indicator
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
90. DOOR OPEN INDICATOR
Is there voltage at
H2-1 on the Electronic
control?
Door Open Light.
Replace Control.
Is there power supplied
to the unit?
NO
Is there voltage at input
of primary fuses?
Is there voltage at
output side of the
primary fuses?
Is there voltage across
terminals 1 & 2 of
transformer primary?
Plug unit in and run
it.
Correct wiring
between primary
fuses and power
supply.
Replace primary
fuse(s).
Correct wiring
between primary
fuses and
transformer.
Replace
transformer.
Is there voltage at
the input of the
secondary fuse?
Is there voltage at
output side of
secondary fuse?
Correct wiring
between secondary
fuse and
transformer.
Replace secondary
fuse.
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Is there voltage at
N.O. of door
switch?
Is there voltage at
N.O. of lint drawer
switch?
Check for proper
operation replace if
necessary.
Correct wiring
between N.O. on lint
drawer and COM on
door switch.
Correct wiring
between N.O. and
output of secondary
fuse.
Check for proper
function of door
switch replace if
necessary.
Correct wiring
between H2-1 of
electronic control
and COM of lint
drawer switch.
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
Single and stacked
units. Gas, steam and
electric heat. Single
and three phase
supply.
Door open
Reference voltage
checks to transformer
neutral.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
TMB250S
Is there voltage across
terminals 2 & 3 of
transformer
secondary?
Is there voltage at
COM of lint drawer
switch with lint
panel closed?
With door closed is
there voltage to
COM of door
switch?