76
Media > Ribbon > Ribbon Calibrate
Determines the amount of ribbon remaining by performing a forward or
reverse move.
Standard Normal forward and reverse ribbon calibration.
Forward Only Forward only ribbon calibration.
Factory Default Standard
IMPORTANT
When GPIO Print & Apply is set to Enable, Ribbon
Calibrate is set to Forward Only. This automatic
setting of the Ribbon Calibrate menu occurs only
once per power cycle and only if the menu is
changed with the control panel.
Media > TOF
Media > TOF > TOF Detect Fault
Allows selection of three different TOF (Top-of-Form) detection faults. The
printer displays a Gap Not Detected fault and stops printing when media has
advanced a distance equal to X or more times Media > Image > Label Length.
1 Label The Gap Not Detected fault is declared after 1 label.
3 Labels The Gap Not Detected fault is declared after 3 labels.
9 Labels The Gap Not Detected fault is declared after 9 labels.
Factory Default 3 Labels
IMPORTANT
The correct Label Length value, equal to the
physical length of the installed label, must be
entered in Media > Image > Label Length.