EasyManua.ls Logo

Process Technology Lufran LUF Series - System Specifications

Process Technology Lufran LUF Series
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
M-43-25 LUF-Series Lufran Manual
Revision - Date 03-01-04-18 Standard outlet, Standard Interface
Engineering Information (Continued):
System Specifications:
Product
LUF-series, Lufran fluoropolymer inline water heater
Available Wattages
24kW 312kW
Refer to model number label for the wattage of any specific unit
Available Voltages
380V 600V, 50/60Hz, 3 phase only
(Lower voltages available with special construction, consult factory for
details)
Cabinet dimensions and
unit weight:
Width Depth Height Weight
24kW 72kW
508mm (20-in) 769mm (30.25-in)
2123mm
(83.57-in)
270 kg
(595 lbs)
105kW – 156kW
712mm (28-in) 769mm (30.25-in)
2123mm
(83.57-in)
340 kg
(750 lbs)
195kW 312kW
1220mm (48-in) 769mm (30.25-in)
2123mm
(83.57-in)
682 kg
(1500 lbs)
Wetted surfaces:
Heating elements
PTFE fluoropolymer
Columns and plumbing
PVDF
o-rings
Chemraz®
Operating temperatures:
Process inlet
50°C maximum
Process outlet Up to 95°C, depending upon operating conditions
Temperature accuracy
+/- 3°C, depending upon operating conditions
Ambient air temperature
30°C maximum
Water flow rate range
1 l/min (0.25 gpm) to 200 l/min (50 gpm)
Water pressure range
Minimum 69 kPa (0.69 bar, 10 psi)
Maximum 690 kPa (6.9 bar, 100 psi)
Purge gas flow rate
required (minimum):
24kW 72kW
141 l/hr (5 scfh)
105kW 144kW
282 l/hr (10 scfh)
210kW 288kW
564 l/hr (20 scfh)
Purge gas pressure range
Minimum 175 kPa (1.75 bar, 25 psi)
Maximum 690 kPa (6.9 bar, 100 psi)