M-43-25 LUF-Series Lufran Manual
Revision - Date 03-01-04-18 Standard outlet, Standard Interface
Figure 2: Model/Serial Number Label
Engineering Information (Continued):
Model Number (Continued):
Provided below is an example of a typical model number along with an explanation of each part. This key
will help you understand your model number.
Model number example:
LUF-130-3LL6-SK
Heater kilowattage rating. The table provided below identifies the standard available wattage
ratings and the number of heater columns needed to provide that amount of Wattage.
Heater
Model
Number
Heater
Wattage
(W)
Number Of
Heater
Columns
Wattage
Per Heater
Column
(W)
Heater
Model
Number
Heater
Wattage
(W)
Number Of
Heater
Columns
Wattage
Per Heater
Column
(W)
024
24,000 1 24,000
144
144,000 2 72,000
036
36,000 1 36,000
156
156,000 2 78,000
052
52,500 1 52,500
195
195,000 3 65,000
065
65,000 1 65,000
210
210,000 4 52,500
072
72,000 1 72,000
260
260,000 4 65,000
078
78,000 1 78,000
288
288,000 4 72,000
105
105,000 2 52,500
312
312,000 4 78,000
130
130,000 2 65,000
Heater Voltage. The first character following the heater Wattage will describe the rated Voltage of
the heater. Please note that all heaters are rated for Three-Phase power.
Heater
Model
Number
Rated
Voltage
(V)
Heater
Model
Number
Rated
Voltage
(V)
1
208
6
480
2
240
7
440
3
380
8
575
4
400
9
220
5
415
10
200