USR-W630s User Manual
pusr.com
- 35 -
Figure 39.
Items
Description
Default
Network AT
Instruction
Whether to enable network AT commands. ON: enabled / OFF:
disabled
ON
AT Data Header
Password for network AT commands
atnetcmd#
Serial Heart
ON: enable sending heartbeat packets to the serial port
OFF: disable sending heartbeat packets to the serial port
OFF
Heartbeat Type
HEX: hexadecimal type
ASCII: character type Refer to section 8.2.7.2 for heartbeat
packet details
HEX
User-Defined
Packet
Content of the heartbeat packet
NULL
Heartbeat Interval
Interval at which heartbeat packets are sent, in seconds
60
Serial Binding
COM1-485: use 485 channel for data communication
COM2-232: use 232 channel for data communication
COM1+COM2: use RS232 or RS485 channel for data
transmission
COM1+COM2
Network
Reconnect
Without Data
Trigger reconnection if no data is received from each channel
within the set time. Applicable to non-HTTP protocols, see
details below for specifics
OFF
Reconnect
Detection
Interval(s)
Set time interval, in seconds
3600