4 FUNCTIONAL DESCRIPTION
4.1 Operating Modes
Day Mode This is the state of the panel when unset. Fire, Personal Attack and Tamper inputs,
however, remain active 24 hours a day. (These are referred to as 24-hour zones).
Set Modes When the panel is set an activation of any Access, Immediate or 24 hour zone will cause an alarm
condition. When an alarm is generated the internal and external sounders will operate for the length
of time programmed and the tone of the extension speaker will be two notes repeated rapidly. The
strobe lamp will also be activated and will continue to operate until the panel is unset.
At the time of setting the control panel, any one of four set modes can be selected. i.e.
Set A: Whole system set; nobody on premises.
Set B: Upstairs off, Downstairs set.
Set C: Upstairs set, Downstairs off.
Set D: Garage and kitchen off, remainder on.
The above are purely examples. The Engineer has the ability at the programming stage to configure
all the circuits to the customer's exact requirements.
4.2 Entry / Exit Mode
Entry When the panel is set and an Entry / Exit zone is triggered the Entry timer will begin to countdown.
During this period an Entry tone (single repeated bleep) will be produced by the extension speaker
and any zones which are programmed as Access zones will be ignored.
If either user code is entered before the end of the count down period the panel will return to unset
mode. If the timer is allowed to elapse before a user code is entered the panel will go into an alarm
state. In this case the system needs to be 'Unset'
Exit With the panel in ‘day’ mode, if a user code is entered the Exit timer will begin. If all the Immediate
zones are clear, then the Exit tone will be heard. Leave the protected area by the predetermined Exit
route. As you trigger access zones the tone will change temporarily to a repeated low tone. When all
the zones are clear, the Exit tone will continue again until the end of the time-out period. The panel will
then be set.
Rins163 Issue 9 Page 11