Enter for final door.
Enter for silent set.
11.11.48 Final Door
Enter
followed by the time required in seconds ( to seconds) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps. Final door delay is factory
set to seven seconds. If the exit door is reopened the delay is reset and the countdown commences when
the exit door is finally closed.
11.11.49 Exiting Engineer Mode
Enter
(Where is the 4 digit Engineer Code).
11.11.50
SYSTEM FAULTS
There are 8 fault conditions automatically detected by the Atlas. The user is informed of a fault via the fault LED. This will
illuminate and an error tone will be emitted every 5 seconds when the panel is in day mode, press the
key to stop the
error tone. The fault ! will remain on until the fault has been corrected.
To determine the fault go into the log by entering
the fault will be displayed.
1 Bell Fuse Failure
2 Auxiliary Fuse Failure
3 Battery Missing
4 Low Battery Voltage
5 Mains Failure
6 Line Fail PC (the onboard telephone connection has failed)
7 Line Fail Digi (the off-board communicator has activated the LNF connection)
8 Failure to communicate
Enter
to exit.