11 ATLAS 8 PLUS LED - PROGRAMMING
11.1 Factory Defaults
The panel is pre-programmed to the factory settings shown below.
Master User code : 1234 (0000-9999)
Manager : 5678 (0000-9999)
Engineer code : 9999 (0000-9999)
Bell timer : 20 minutes (programmable 2 to 20 mins)
Bell delay : 0 minutes (programmable 0 to 20 mins)
Entry : 30 seconds (programmable 2 to 255 secs)
Exit : 30 seconds (programmable 2 to 255 secs)
Event log : Engineer reset of log
Downloading access code : 1234
Group reporting : Group1=1, Group2=1, Group3=1
Dial in : Enabled
Zones : End of line resistor
Programmable Outputs : Off
System Option 1 : End of line zone
User Log Reset Disabled
Tone Dial
Internal Sounder Only On Tamper Activation
System Option 2 : 24 Hour Test Dial
Dial In enabled
Timed Exit
Audible P.A. Zones
System Option 3 : Engineer Power Up NVM Reset
Engineer System Reset Disabled
User Omit Enabled
Door Chime On Push To Set Enabled
System Option 4 : Anti Code Reset Disabled
Open zone display Disabled
No alarm on line fail - STU
No alarm on line fail - PC
System Option 5 : Alarm Active Low
P.A. Active Low
Fire Active Low
Confirmed Active Low
System Option 6 : Abort Active Low
Open Active High
Spare
Spare
System Option 7 : Alarm Restoral Reporting Off
P.A. Restoral Reporting Off
Fire Restoral Reporting Off
Confirmed Alarm Restoral Reporting Off
System Option 8 : Abort Restoral Reporting Off
Spare
Spare
Spare
System Option 11 : Alarm On
P.A. On
Fire On
Confirmed Alarm On
System Option 12 : Abort Alarm On
Set / Unset Off
System Faults Off
System Option 13 : Alarm On
P.A. On
Fire On
Confirmed Alarm Off
System Option 14 : Abort Alarm On
Set / Unset on
System Faults Off
System Option 15 : Alarm On
P.A. On
Fire On
Confirmed Alarm Off
System Option 16 : Abort Alarm On
Set / Unset off
Rins163 Issue 9 Page 31

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ATLAS 8 PLUS and is the answer not in the manual?

Pyronix ATLAS 8 PLUS Specifications

General IconGeneral
BrandPyronix
ModelATLAS 8 PLUS
CategoryKeypad
LanguageEnglish

Related product manuals