12.11.42 System Option 20 Set D Send Options cont.
Enter followed by - . The RKP will toggle and X as the numbered keys are pressed.
Key Press
Display 1 2 3 4
Abort On Set / Unset On System Fault On Spare
X
Abort Off Set / Unset Off System Fault Off Spare
Enter to accept.
12.11.43 System Option 21
Enter
followed by - . The RKP will toggle and X as the numbered keys are pressed.
Key Press
Display 1 2 3 4
Selectable resets Reset omit Global Tamper Negative
Return
Disable telephone line
monitoring
X
All resets No reset omit Global Tamper Volt Free
Loop
Enable telephone line
monitoring
Enter to accept.
12.11.44 Set A Set Option
Enter
Enter for timed exit,
Enter for push to set or
Enter for final door.
Enter for silent set.
12.11.45 Set B Set Option
Enter
Enter for timed exit,
Enter for push to set or
Enter for final door.
Enter
for silent set.
12.11.46 Set C Set Option
Enter
Enter
for timed exit,
Enter for push to set or
Enter for final door.
Enter for silent set.
12.11.47 Set D Set Option
Enter
Enter
for timed exit,
Enter
for push to set or
Enter for final door.
Enter for silent set.