8 Shock Sensor Reset.
11.11.2 Programmable Output 2
Enter
followed by - for following options:
0 OFF (programmable output 2 not used).
1 PIR remote LED enable.
2 PIR latch memory.
3 Limited User Code 7 Switches Output for 5 secs.
4 Output switch reflecting setting and unsetting of panel.
5 Follow zone. Refer to 11.11.25 for zone allocation.
6 Follow line fail.
7 Follow kiss off.
11.11.3 System Option 1
Enter
followed by - . The RKP LED will toggle on and off as the numbered keys are pressed.
Key Press
Display Alarm Tamper P.A. Fire
ON
Double pole zone User log reset enabled External and internal
sounder on tamper
activation
OFF End of line zone User log reset disabled Tone dial Internal sounder only
on tamper activation
Enter to confirm programming.
11.11.4 System Option 2
Enter
followed by - . The RKP LED will toggle on and off as the numbered keys are pressed.
Key Press
Display Alarm Tamper P.A. Fire
ON 7 Day test dial Dial in BSIA test dial Silent P.A zones
OFF 24 Hour test dial No dial in No BSIA test dial Audible P.A. zone
Enter to confirm programming.
11.11.5 System Option 3
Enter
followed by - . The RKP LED will toggle on and off as the numbered keys are pressed.
Key Press
Display Alarm Tamper P.A. Fire
ON
Engineer code NVM
reset
Engineer system reset
enabled
User omit disabled Door chime on push to
set disabled
OFF
Power Up NVM reset Engineer system reset
disabled
User omit enabled Door chime on push to
set enabled
Enter to confirm programming.
11.11.6 System Option 4
Enter
followed by - . The RKP LED will toggle on and off as the numbered keys are pressed.
Key Press
Display Alarm Tamper P.A. Fire
ON
Anti code reset enabled Open zones displayed Alarm on line fail -
STU
Alarm on line fail - PC
OFF
Anti code reset
disabled
Open zones disabled No alarm on line fail -
STU
No alarm on line fail -
PC
Enter to confirm programming.
11.11.7 Programmable Re-sets