EasyManua.ls Logo

Pyronix ATLAS 8 PLUS - Programming Set Modes; Setting the Alarm Bell Time; Setting Entry Time; Setting Exit Time

Pyronix ATLAS 8 PLUS
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.6 Programming Set Modes.
Any zone may be programmed to be any one of the following:
Entry / Exit Access immediate omit momentary key
latched key tamper personnal attack 24 hour fire
The attribute for each zone is changed by pressing
or
until the required attribute appears in the display. When
the display shows the required attribute press the
key to store the zone attribute. If the required attribute is already
shown press the
key to go to the next zone.
NOTE: On pressing
after selecting the attribute for zone 8, the programme will be stored automatically.
To programme Set A enter , to programme Set B enter
to programme Set C enter and to programme Set D enter
Should you wish to view any zone status within a Set mode use the same procedure, but do not scroll the keys.
12.7 Setting the Alarm Bell Time
To adjust the alarm bell cut off time. Enter
followed by the required time in minutes ( to minutes) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The alarm bell cut off time for the Atlas is factory set to 20 minutes.
12.8 Setting Entry Time
To set the required Entry time. Enter
followed by the time required in seconds ( to seconds) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Entry time is factory set to 30 seconds.
12.9 Setting Exit Time
To set the required Exit time Enter
followed by the time required in seconds ( to ) followed by .
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The Exit time is factory set to 30 seconds.
12.10 Changing the Engineer Code
Enter
then The old Engineer Code - gives an audible acceptance tone
(Factory Set at 9999)
then
the new Engineer Code - gives an audible acceptance tone
then
the new Engineer Code again- gives an audible acceptance tone
If an incorrect key is entered an error tone will be given and the function ended.
Rins163 Issue 9 Page 49