13 TECHNICAL SPECIFICATION
13.1 Power supply
Mains input
Voltage: : 230V +/- 10%
Current: : 250mA
Fuse: : F1 250mA slow blow T250mAH ceramic
PCB input : 17V a.c.
Fuses
Low voltage output fuse – Bell : F1 1A quick blow F1AL glass
Low voltage output fuse – AUX : F2 1A quick blow F1AL glass
In-Line fuse 17VAC : F3 2A quick blow F2AL glass
Battery charge voltage : 13.7 V d.c.
Rechargeable battery capacity : 12V sealed lead acid, 2.8 to 7 AH.
13.2 Control PCB
Current consumption
(day mode) : 130mA.
(set mode) : 130mA.
(alarm) : 130mA.
Auxiliary DC output supply : Regulated 13.2V d.c. for use with PIR, microwave and shock sensors.
Extension Speaker load : 16 to 32 Ohms.
Bell : 500mA.
Strobe : 500mA.
PR1 / PR2 : 250mA.
Alarm bell time : 2 to 20 minutes (software programmable).
Zone type : Normally closed loops, which activate when opened or short circuit.
Zone loop current : 0.76 to 1.03mA.
Zone activation resistance : 6.9K Ohms (minimum).
Zone loop activation timer : 0.35 seconds.
Exit timer : 2 to 255 seconds.
Entry timer : 2 to 255 seconds.
13.3 Mechanical
Dimensions : 228 x 243 x 75 mm.
Case material : 1.2mm (0.8mm export) thick Mild steel with screw fixing front cover.
Colour : White (grey export).
Weight excluding battery : 2.6Kg.
13.4 Environmental
Operating temperature : 0 to +40
0
C (+32 to +104
0
F).
Storage temperature : -20 to +60
0
C (-4 to +140
0
F).
13.5 Cleaning
DO NOT use strong detergents to clean this control panel. To remove any dirt or grime, wipe with a clean damp cloth
ONLY