EURO 46, 162 & 280 Programming Manual
Page: 16
6. 'Enter Name' will be displayed. Enter the name of the input and
press . This will be displayed if it is activated or when a fault
occurs.
7. 'Enter Location' will be displayed. Enter the location of the input
and press . This will be displayed if it is activated or when a
fault occurs after the name of the input has been shown.
8. Press or to select another input to program (01-66) or
press the key to return to the Engineer menu.
4.6.1 Shunt Inputs
A shunt group may consist of any number of inputs programmed as Intruder, Day Alarm and Entry Route
types. These must all be allocated in the same Area. NOTE: These will need to be programmed first.
The inputs in the shunt group/list will only activate after 10 seconds of the nominated shunt input. For
example, if input 1 is programmed as ‘Shunt Input’, and inputs 2 and 3 are programmed as “Day Alarm”,
then once input 1 has been opened, after 10 seconds inputs 2 and 3 become active. (Inputs 2 and 3 will
not become live after 10 seconds if either detector is in active).
Action Status Outputs
Shunt Input closed (shunted)
Inputs within the shunt list are
inactive
The ‘Follow Input’ output is live
Shunted Input triggered No response
Shunt Input opened (unshunted) -
The ‘Follow Input’ output clears. The
‘Shunt Fault’ output is live for 10
seconds.
After 10 seconds Inputs in the shunt list are active Indications off.
Shunt Input opened with an active
detector (attempting to unshunt)
-
The ‘Follow Input’ output clears. The
‘Shunt Fault’ output pulses until the
shunt is reset or the input fault
clears.
Active input clears -
The ‘Shunt Fault’ output is live for 10
seconds. (Will not function correctly
on an ATE pin).
After 10 seconds Inputs in the shunt list are active Indications off.
Shunted input triggered (whilst not
triggered)
Normal input response
(Note: depends upon the status of
the Area in which the shunt is
located).
Change Inputs Programming: Shunt Inputs
1. Press or to scroll to 'CHANGE INPUTS'. Press .
2. Press or to select the input to program. Press .
3. 'Input Type' will be displayed. Enter '18' for 'Shunt Input' Press
4. 'Shunt Inputs' will be displayed. Enter the inputs to include in the
Shunt List, after each input press . Each input will scroll on the
bottom line of the LCD display.
NOTE: Inputs programmed as 'Intruder, Tamper, Day Alarm or Entry
Route' cannot operate as a Shunt Input.
5. 'Input Area' will be displayed. Select the Area's to be assigned to
the input and press .
Input Areas
[ A ]
Input Attribtes?
Enter Name
_
Enter Location
_
CHANGE INPUTS?
Input [01]
Input 01
Input Type [18]
Shunt Input
Shunt Inputs?