EURO 46, 162 & 280 Programming Manual
Page: 21
4.9 Change Timers
This function controls all timers of the EURO control panel.
4.9.1 Timers
For a list of all timers, refer to Appendix C (page 45).
Most commonly used timers:
Entry Time (0-255 seconds), Exit Time (0-255 seconds), Siren Time (2-15 minutes), Confirm
Time (1-99 minutes), Wireless Supervision Time (0-99 hours).
NOTE: The timer for inputs on 'Soak Control' is in the function 'ENGINEER TESTS'.
Change Timers Programming
1. Press or to scroll to 'CHANGE TIMERS'. Press .
2. 'A Entry Time' will be displayed. Enter the time and press .
Refer to Appendix C (page 45) for all timers and enter the time on
the required function and press for the next timer.
3. Press to return to the Engineer menu.
4.10 Date and Time
All log entries and the system display include the time and date. This is also programmed in the
Master Manager Mode.
NOTE: Please note that powering down the system will reset the time and date information.
4.10.1 Year, Month, Day, Hours, and Minutes
Enter the year, month, day, hours and minutes.
4.10.2 DST Adjust
Enable or disable the 'Day Saver Time Adjust' as required.
Set Date and Time Programming
1. Press or to scroll to 'SET DATE AND TIME'. Press .
2. 'Year' will be displayed. Enter the year and press . Repeat for
Month, Day, Hours and Minutes and press .
3. 'DST Adjust' will be displayed. Press or to enable or
disable the function and press .
4. Press to return to the Engineer menu.
4.11 Exit Modes
The ‘Exit Modes’ operate the Setting procedure of the EURO control panel system. The following Exit
Modes are available:
4.11.1 Exit Modes
[0] Timed: The EURO control panel system will set when the programmed 'Exit Time' has
expired (Refer to ‘CHANGE TIMERS' (page 21)).
NOTE: This is NOT suitable for systems installed to comply with BS8243.
[1] Final Door: The EURO control panel system will set when an input programmed as 'Final
Exit' is either closed (if the input was opened when setting started) or it is opened and closed.
'Final door' is used for the ‘lock set’ operation; securing the lock completes the setting procedure
and unlocking starts the entry time.
[2] Timed/Final: The EURO control panel system will set when a 'Final Exit' input has been
closed, or when an 'Exit Time' has expired. The 'Final Exit' input will override any 'Exit Time'
programmed if opened/closed.
NOTE: This is NOT suitable for systems installed to comply with BS8243.
[3] Push to Set (PTS): The EURO control panel system will only Set when a ‘Push to Set’
button has been pressed. This function will override the programmed Exit Time.
CHANGE TIMERS?
A Entry Time
[030]
SET DATE & TIME?
Year (00-99)
[07]
DST Adjust?
No [0]