EURO 46, 162 & 280 Programming Manual
Page: 4
2. System Overview
2.1 System Overview
EURO EURO 46
Double Pole
EURO 46
End of Line
EURO 162
iD
EURO 162
End of Line
EURO 280
iD
EURO 280
End of Line
Inputs (max) 46 162 280
Inputs (max iD) - 150 240
Inputs (max wireless inputs)
Using EURO-ZEM32-WE
32
(1 x ZEM32-WE)
96
(3 x ZEM32-WE)
96
(3 x ZEM32-WE)
Inputs (max wired ZEMs)
EURO-ZEM8+
4 4 4 18 7 30
Set Points (Max) $ 6 16 30
Of which max keypads 6 16 30
Other Devices Max $ 5 15 29
Wireless Bells 2 2 2
Level Sets 6 12 14
Full Areas 6 12 14
Wards (Max) 5 15 29
Shunts 23 81 140
Wireless Keyfobs 32 32 32
User / Manager Codes £ 75 200 500
Duress / Guard Codes 10 20 20
Logs Mandatory 750 1000 1000
Logs Access 250 500 500
Logs Optional 250 500 600
Output Modules 2 8 16
EN Grade 3 (2 = Small casing) 3 3
Environment Class 2 2 2
Comms Modem, ATE Pins Modem, ATE Pins Modem, ATE Pins
Modem Type EURO DIGI-1200 (PSTN) EURO-073-ARM EURO-073-ARM
MSX card compatible
Autoset & Gates
Shunt, Day Alarm, Unset Input
Types
Follow Input
Special Log
Intelligent Inputs Multiple Multiple Multiple
Display when Set
Selectable Resistance Ranges
Download When Set
Remote Set and Soak
Event Signalling to Insite
Dial Out Menu
Upload/
Commission
Upload/
Commission
Upload/
Commission
Power Supply
EURO 46S: 1.5A (small casing)
EURO 46L: 2A (large casing)
EURO 162/280: 2.5A
Rating Grade 1: 2.25A
Rating Grade 2: 1.4A
Rating Grade 3: 0.9A
£ Includes Engineer and Master Manager codes
$ Includes keypads, tag readers, and ZEM2Ps