4.25 Clean Start
It is recommended that a factory default (Clean Start) is performed after initial power up to ensure
that the correct defaults are applied. Refer to page: 39 for a list of all defaults.
4.25.1 Clear Wireless Data
If this function is not accepted, then all wireless inputs, wireless external sounders will be still
active on the EURO-ZEM32-WE (if connected).
4.25.2 Clear Codes
If this function is not accepted, then all codes, tags and keyfobs will be still present on the EURO
control panel.
4.25.3 Clear Logs
If this function is not accepted, then all event logs will be still present on the EURO control panel.
If a DualCom Inside module is connected, all the GPRS information can be cleared with the
function 'Clear DualCom Inside?'.
NOTE: If everything is defaulted, the system memory will also be restored to factory defaults
except the following:
Keypad address '0' remains enabled at all times & the keypad in use remains enabled
Additional keypads connected will keep the area information
Clean Start Programming
1. Press or keys to scroll to 'CLEAN START'.
Press .
2. a) Enter the default code 2000 for Grade 3 defaults
b) Enter the default code 2002 for Grade 2
defaults.
3. 'CLEAR WIRELESS DATA' will be displayed. To delete
all wireless data (any inputs and bells that are
learned) press , or press to keep the
wireless data.
4. 'CLEAR CODES' will be displayed. To delete/default
all user code, tag and keyfob data, press , or
press to keep the codes that are programmed.
5. 'CLEAR LOGS' will be displayed. To delete all event
log data press , or press to keep the event
log data.
CLEAN START?
CLEAN START?
[ ]
Please Wait
Panel has been
clean started!