EasyManua.ls Logo

Pyronix Castle EURO 46 Series

Pyronix Castle EURO 46 Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EURO 46, 162 & 280 Programming Manual
Page: 26
4.16 Intelligent Set
When the 'Intelligent Set' function is enabled, the EURO control panel will set in Area B but if a final
exit input is activated (such as a front door) that is programmed on Area A, the EURO control panel
will automatically start setting Area A.
If no Final Exit input is activated during Area B's setting time, the EURO control panel will just set
Area B.
NOTE: The user code/tag/keyfob must be assigned to both Areas A and B.
Intelligent Set Programming
1. Press or to scroll to 'INTELLIGENT SET'. Press .
2. 'Intelligent' will be displayed. Use or to enable / disable
intelligent setting.
3. Press to return to the Engineer menu.
4.17 Site Options
A full range of site options is available to tailor the operation of the system.
Option Function
Set With Fault If ‘YES’: Allows setting with the following faults active: Device fail, Mains fail, Battery
faults, Fuse faults, SMS failure, relay sirens 1&2, relay Strobe faults.
Set With
Tamper+
If ‘YES’: Allows setting with the following faults active: Case tamper and System tampers.
Set With ATS
Fault
If ‘YES’: Allows setting with the following faults active: Telecom line fail, Modem failed,
STU/ATE line fault, STU/ATE one path fail, Digi dial fail, STU/ATE comms fail.
Set With Ward
TFault
If ‘YES’: Allows a ward to be set if mains, battery, telecom line, or other system fault is
present.
Set Fail = Alarm If ‘YES’ = A graduated alarm will be generated when ‘Set Fail’ timer expires (Refer to
'CHANGE TIMERS'), if exit procedure is still incomplete. Set fail output will trigger.
If ‘NO’ = Exit time will continue until the Exit route is clear.
Do Bat Load Test If ‘YES’: Programmes the system to perform a full load test of the battery at 7.00am each
day.
Ward
Misoperation
If ‘YES’ Allows a Misoperation (Abort) signal to be generated without the entry of a valid
code into the system when a ward is operated after an alarm.
Strobe/Squawk
at set
If ‘STROBE’: A ‘STROBE ANY’ output will be activated for 5 seconds as the system arms. If
SQUAWK’: A ‘SIREN ANY’ output will be activated for 5 seconds as the system arms. If
BOTH’ then both of the above will activate for 5 seconds as the system arms. Use with
care, in view of potential security risk.
Re-Arm Omits If ‘YES’: At rearm at the end of the confirmation time, this function will force an input (not
a system tamper) causing an unconfirmed alarm to be omitted, whether it’s still in fault or
not.
Use Level Set If ‘YES’: The system becomes a ‘level set’ (Having one area set only at any one time, e.g.
part sets). If ‘NO’: The system becomes a ‘area’ system (setting more than once area at a
time)
Confirmed When Final Set: Confirmed signal only available after the system is set. Exit Starts: Confirmed
signal available after the exit time has started. NOTE: Not compliant with BS8243.
Note: ‘Exit Starts’ must be selected in order for it to be entered in the logs.
AutoSet Force If ‘YES’ when autoset is in use the panel will still set even if an input is open at the time.
Restrict PIN Use If ‘YES’ the system prevents a pin code being entered on the Entry Time, but allows the
system to be silenced once in alarm.
Enable when BS8243 option 6.4.5 is in use.
Simple Set Enables the ‘simple set’ functionality which allows a user to set the system by pressing the
‘YES’ key and the level set.
PLEASE NOTE THIS FEATURE IS NOT UK COMPLIANT
Invert ATE O/Ps If ‘YES’: ‘Positive Removed’ If ‘NO’: ‘Positive Applied’
Common Lobby If set to ‘YES’, this will automatically select the ‘highest’ exit mode for all partitions. (0 =
Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS). For example, if Area C is selected
as Final Door and the rest of the partitions are selected as Timed, then because Final Door
INTELLIGENT SET?
Intelligent
No [0]

Related product manuals