4.7.6 Set Point In
The keypad needs to also be told which Areas it is operating “in”. For example, a keypad may
only be needed to operate in Area A, but other code users may use the keypad to quick Set other
Areas (such as a cleaner, director, caretaker etc). Therefore if Areas A and B are selected in the
previous options (Set point arms and disarms), but Area A only is selected in ‘Set point in’, then
Area B will quick set once a valid tag/code has been entered. To program Areas operating with
their programmed timer, then the Areas need to be entered into the “Set Point In” function.
4.7.7 Set Point Description
A name and location can be entered here. The name will appear on the display if an alarm has
occurred, the location is used for a more detailed reference if required. E.g. Name = Entrance
Keypad. Location = Hall
Programming Keypads: Assign Keypads/Readers
1. Press or to scroll to 'ASSIGN KEYPADS/READERS'. Press
.
2. Press or to select the address. Press .
3. 'Type' will be displayed. Press 0 to select keypad.Press
4. 'Set Point Sets' will be displayed. Select the area and repeat for
'Set Point Unsets' and 'Set Point In'. Press .
5. 'Set Point Description' will be displayed. Press to enter the
name and location if required.
6. 'Enter Name' will be displayed. Enter the name of the keypad and
press .
7. 'Enter Location' will be displayed. Enter the location of the keypad
and press .
8. Press or to select another device address to program or
press the key to return to the Engineer menu
Programming Readers for Set Point or Unset Only: Assign
Keypads/Readers
1. Press or to scroll to 'ASSIGN KEYPADS/READERS'. Press
.
2. Press or to select the address. Press .
3. 'Type' will be displayed. Press 1 to select reader.Press
4. 'Reader is' will be displayed. Press 0 for 'Set Point' or press 3
for 'Unset Only' Press .
5. 'Set Point Sets' will be displayed. Select the area and repeat for
'Set Point Unsets' and 'Set Point In'. Press .
6. 'Set Point Description' will be displayed. Press to enter the
name and location if required.
7. 'Enter Name' will be displayed. Enter the name of the keypad and
press .
8. 'Enter Location' will be displayed. Enter the location of the keypad
and press .
9. Press or to select another device address to program or
press the key to return to the Engineer menu.
ASSIGN KEYPADS/
READERS?
Address
[0]
Type
Keypad [0]
Set Point Sets
[ A ]
Set Point
Description?
Enter Location
_
ASSIGN KEYPADS/
READERS?
Address
[1]
Type
Reader [1]
Reader is [0]
Set Point
Set Point Sets
[ A ]
Set Point
Description?