EURO 46, 162 & 280 Programming Manual
Page: 30
Engineer Tests Programming: Walk Test
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Use or to select the
different sounds. Press to exit.
3. 'Walk Test' will be displayed. Press .
4. Select the areas that are required to be walk tested and press .
5. A list of all inputs programmed for that area will be displayed on
the keypad. Once an input has been walk tested (i.e. the detector
has activated and deactivated) then the input will be taken off the
list.
6. Once all inputs have been tested, 'Walk Test Completed' will be
displayed. To exit the walk test function at any time press .
7. Press again to go back to the Engineer menu.
Engineer Tests Programming: Soak Control
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Control' will be displayed. Press .
5. Select the inputs that are required to be soak tested. Each input
should be entered, following by . Press once finished.
6. 'Soak Days Left' will be displayed. Select the number of days that
the inputs will be left on soak test and press .
7. 'Initial Soak' will be displayed. Enter the number of days the soak
test will revert to in the event a soak input is triggered during
testing. Press .
8. Press to go back to the Engineer menu.
Engineer Tests Programming: Test Siren, Battery Load Test and
Test Outputs
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Test' will be displayed. Press .
5. 'Test Siren' will be displayed. Press . Any outputs programmed
as 'Siren Any' and 'Strobe Any' will trigger. Press to exit.
6. 'Do Battery Load Test' will be displayed. Press to perform a
battery load test, the voltage will be displayed, followed by
'Battery Passed' if the test has been successful. Press .
7. 'Test Outputs' will be displayed. Press to perform a test on
any output type. For example if '0006' is entered, and the key
is pressed, a 'Confirmed Any' test will be activated. Press to
cancel the test.
8. Press to go back to the Engineer menu.
ENGINEER TESTS?
Sound to play
No Sound [00]
Walk Test?
Walk Test Areas
[ABCD]
Walk Test Inputs
Input 01
ENGINEER TESTS?
Sound to play
No Sound [00]
Soak Control?
Soak Inputs [--]
Soak Days Left
[00]
Initial Soak
[00]
ENGINEER TESTS?
Test Siren?
Do Battery Load
Test?
Testing Battery
13.3V
Test Outputs?