Device Status RED is equivalent to 1 above.
GREEN = GOOD, RED = BAD. All LEDS = Starting test
For a more descriptive reading, press again on the EURO control panel keypad when the
status (above) is shown. The following will be displayed:
Excellent [50 to 100] = OK to install
Good [30 to 49]= OK to install
Weak [0 to 29] = Not OK to install
Missing (no number is displayed) = Not OK to install
Wireless Battery Strength
The diagnostics function also monitors the battery of each input and bell so that any low/bad
batteries can be recognised and replaced. The following will be displayed:
Testing = Waiting for a Battery result
Good = At least 1 month of battery life remaining
Replace = Battery Needs To Be Replaced Immediately
Each input / bell device is tested every 15 seconds.
Diagnostics Programming: View PSUs.
1. Press or to scroll to 'DIAGNOSTICS'. Press .
2. 'View PSUs' will be displayed. Press .
3. 'Endstation PSU' will be displayed and the power supply reading of
the EURO control panel will be shown. Press .
4. 'ZEM PSU' will be displayed. Enter the address of the ZEM installed.
The power supply reading will be displayed and press .
5. Repeat the above for any Output expanders, keypads and readers
installed. Press to return to the sub-menu.
Diagnostics Programming: View Inputs.
1. Press or to scroll to 'DIAGNOSTICS'. Press .
2. 'View PSUs' will be displayed. Press .
3. 'View Inputs' will be displayed. Press .
4. 'Endstation Inputs' will be displayed. To view the Endstation Inputs
press . The status will be displayed. Press again to view
the resistance values. Press to return to the sub-menu.
5. Repeat the above for the sub-menu's 'Wireless Inputs', and 'ZEM
Inputs' (selecting the address first). Press to return to the sub-
menu.
DIAGNOSTICS?
View PSUs?
Endstation PSU
13.3V
ZEM PSU [00]
DIAGNOSTICS?
View Inputs?
Endstation
Inputs?
00