EURO 46, 162 & 280 Programming Manual
Page: 34
4.22.5 Roving Dial
This option (when set to 'No') prevents anyone dialling into the panel using roving dial from the
software. To comply with DD263:2010 this option must be defaulted to 'No'.
4.22.6 Modem Speed
For future use. Make sure this is set to [1] HIGH.
4.22.7 Prefix Tel No
If, for example a '9' is required to dial an ‘outside’ line, this must be entered here.
4.22.8 ARM PC Telephone Number
This is the phone number of the PC modem where the software is installed for performing the
'Automatic Remote Maintenance' (ARM) service. Press a button to add any symbols: ‘,’ = 2
second pause, ‘+’ for roaming calls. This is used in conjunction with the ‘DIAL OUT MENU’
function (refer to page: 37).
4.22.9 Program PCs
Up to 4 x PC modem numbers may be programmed, i.e. the software maybe installed on four
different PCs (office PC, home PC, etc). These are selected in the 'Dial Out Menu' in the Master
Manager menu (refer to the user manual (RINS1527)).
The signalling events are unique to each PC modem number.
Send Alarms: If enabled, the panel will report ‘alarm’ events to the PC running UDL software.
Send Faults: If enabled, the panel will report any ‘fault’ events to the PC running UDL software.
Send Set / Unset: If enabled, the panel will report ‘open/close’ (set/unset) events to the PC
running UDL software.
Send Access Control: If enabled, the EURO control panel will report any ‘access control’ events
to the PC running UDL software.
4.22.10 UDL Password
This password is used to identify the UDL connection. Make sure the password here and on the
software are the same.
4.22.11 Redials
The number of redials that it will call to the software before it fails.
Set Up Downloading Programming
1. Press or to scroll to 'SET UP DOWNLOADING'. Press .
2. 'Download by' will be displayed. Use or to scroll through
the different options and press to select.
3. 'Security Mode' will be displayed. Use or to scroll through
the different options and press to select.
4. 'Telecom Line' will be displayed. Use or to scroll through
the different options and press to select.
5. 'Number of Rings to Prime' will be displayed. Enter the number of
rings and press .
6. 'Roving Dial' will be displayed. Use or to enable or disable
the roving dial. Press .
7. 'Modem Speed' will be displayed. DO NOT ALTER. Press .
8. 'Prefix Tel No' will be displayed. Enter any prefix number if
required and press .
9. 'ARMPC Tel No' will be displayed. If 'Automatic Remote
Maintenance' is being used, enter the PC modem number here and
press .
10. 'Program PCs' will be displayed. Select the PC number and press
. Enter the modem number and press .
SET UP
DOWNLOADING?
Download by
Modem [1]
Security Mode
Auto-Answer [0]
Telecom Line
Dedicated [0]
Number of rings
to prime [01]
Prefix Tel No
_
ARMPC Tel No
_