EasyManuals Logo

Pyronix EURO 46 V10 User Manual

Pyronix EURO 46 V10
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
23
EURO 46 V10 User Manual
SMS Phonebook
If SMS text is programmed, there can be up to 10 mobile numbers also programmed which
can be changed in this function. If “do not use” is shown on the display of a number, then a telephone
number already exists that is communicating to an Alarm Receiving Centre (this can only be changed
by your engineer).
SMS PHONEBOOK
SMS Numbers
[01]
Mobile No. _
Press b or h to scroll to ‘SMS PHONEBOOK’.
Press f.
Press b or d to scroll through the different
telephone numbers. Press f.
Enter the mobile number. Press f.
Press b or d to enable or disable the number.
Press f.
Walk Test
WALK TEST?
Walk Test Areas
[01ABCD]
Walk Test
Input 01
Walk Test Input
[01]
Press b or h to scroll to ‘WALK TEST’. Press
f.
Select which level/area to walk test. Press f to
walk test all inputs or press the h to walk test an
individual input.
PLEASE NOTE: Only select one area to walk test at
a time.
Walk test the inputs scrolling on the display. After all
inputs have been walk tested successfully ‘Walk Test
Completed’ will be displayed.
Walk Test Individual Inputs
Press b or d to scroll through the different inputs
and press f to walk test that input.
The ‘Walk Test’ function allows the testing of all programmed inputs on the alarm system.

Other manuals for Pyronix EURO 46 V10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix EURO 46 V10 and is the answer not in the manual?

Pyronix EURO 46 V10 Specifications

General IconGeneral
BrandPyronix
ModelEURO 46 V10
CategorySecurity System
LanguageEnglish

Related product manuals