SPECIFICATIONS
EN COMPLIANCE STATEMENT continued…
Notes for EN50136-1:2012 Compliant Installations:
The IQ Panel 2 has an integral communicator using the Qolsys proprietary serial interface. The communicator circuitry operates in pass-
through mode and it does acknowledge the alarm to the compatible controls panel after an acknowledgement has been received from
the compatible alarm receiver.
The IQ Panel 2 integral communicators are compatible with the following receivers: Sur-Gard System I-IP Receiver, version 1.41+. Sur-
Gard System II Receiver, version 2.14+, Sur-Gard SG-DRL3-IP, version 2.36+ (for Sur-Gard System III Receiver), Sur-Gard SG-DRL4-IP
version 1.29+ (for Sur-Gard System IV Receiver), and Sur-Gard SGDRL5-IP version 1.04+ (for Sur-Gard System 5 Receiver).
1. The IQ Panel 2 integral communicator is monitored by the control panel and it is programmed via the programming menu available
from the website portal.
2. The HSPA 3G/LTE Cellular path is immune to conducted and radiated RF fields with levels up to 10V/m as tested per EN50130-4
Standard.
3. The IQ Panel 2 integral communicator conforms with radiated emissions levels for Class B equipment as per standards
EN61000-6-3/EN55032/CISPR32.
4. The IQ Panel 2 integral communicator has one cellular communication path using 900/1800/2100 MHz Public Cellular Network and
one Wi-Fi 2.4GHz communication path. It can use on the cellular path (SP2) or both in backup configuration (DP1, using cellular as
primary path and Wi-Fi as back-up).
5. The IQ Panel 2 integral communicator used AES128 encryption algorithm for communication with compatible receivers. The AES 128
encryption of data communication ensures substitution and information security.
6. The IQ Panel 2 integral communicator has been tested for compliance in conjunctions with the following applicable standards:
EN50136-1:2012, EN50136-2:2013, EN50131-10:2014, ATS configuration: SP2 and DP1.
For EN50131-1:2006/A1:2009/A2:2017 compliant installations, the following programming options shall be set as described:
Test transmission interval set to 24h for SP2 and DP1 configuration.
IQ Panel 2 integral communicator has been certifies by Telefication in accordance with EN50131-1:2006/A1:2009/A2:2017,
EN50131-10:2014 requirements for Grade 2, Class I and EN50136-2:2013 Configuration: SP2, DP1.