INSTALLER/DEALER SETTINGS
Loss of Supervisory Signals for Non
Emergency Sensors
Select the length in hours (4,12,24) before reporting a loss of supervision on security
devices. Not approved for CE/EN Grade 2.
Loss of Supervisory Signals for
PowerG Non Emergency Sensors
Select the length of time (20, 30 min, 1, 2, 4, 12, 18 hours) before reporting a loss of
supervision on PowerG security devices. For EN Grade 2, the supervision window shall be
set for 20 minutes.
Loss of Cell Signal Timeout
Select the length in minutes (10-120) before reporting a loss in cellular signal.
Choose Never, Daily (required for EN Grade 2), Weekly or Monthly when enabling the
communication test.
SIA Limits
NOTE: for EN Grade 2 set entry delay (45s) and
exit (30s) delay.
When enabled, the range for entry and exit delays is as follows:!
-Entry delay: 30-240 seconds, Exit Delay: 45-254 seconds!
When disabled, the range for entry and exit delays are as follows:!
-Entry delay: 5 to 240 seconds, Exit delay: 5 to 254 seconds
When enabled the range for Dialer Delay is: 15 to 45 seconds!
When disabled the range for Dialer Delay is: 0 to 254 seconds