PROGRAMMING
INSTALLER/DEALER SETTINGS
Setting
Default
Description
EN Grade 2
Disabled
This setting is required for EN Grade 2 compliance on the Panel and must be Enabled for
EN Grade 2 installations. When Enabled, the following behaviors and/or settings are
changed automatically:
-
Entry Procedure (EU) - follows entry procedures and alarm transmission delays
specified by EN 50131
-
Disables the “Auto Bypass” setting so that the Panel will protest arming when sensor
and panel trouble conditions are present (i.e. Open, Tamper, Low Battery, etc)
-
Trouble condition alerts can not be acknowledged until the condition is resolved
-
Trouble beeps are expanded to include fault indications required by EN 50131
-
“Screen Lock” setting is enabled automatically. Screen will lock 30 seconds after
Disarming
-
A new icon called “EU Events” is added to the “Settings" page which records mandatory
history events specified by EN 50131.
-
“Loss of Supervisory Signals for PowerG Non-Emergency Sensors” is set to 2 hours by
default.
-
“LED Indicator” setting is Disabled automatically.
-
“Partitions” setting is not available.
-
“Dealer or Installer Access Requires User Permission” setting is Enabled automatically.
EU Event Swinger Shutdown Count
3
Determines the number of times a particular event will record to “EU Events” log before
shutdown. The count (3-10) will reset after and arm or disarm event. NOTE: This setting is
greyed out and not selectable unless EN Grade 2 is Enabled.