PROGRAMMING
SECURITY AND ARMING
Setting
Default
Description
Allow Master Code to Access
Security and Arming
Disabled
Allow the master code to access these features and settings.
Normal Entry Delay
30 Secs
How much time users have to enter their code after opening a door (30-240secs). With SIA
limits disabled the minimum time can be set to 5 secs.
NOTE: For EN Grade 2 the maximum entry delay should not exceed 45s
Normal Exit Delay
60 Secs
How much time users have to exit the location before the panel arms itself (30-254secs). With
SIA limits disabled the minimum time can be set to 5 secs. Door/Window group 10 follows the
“Normal Exit Delay” NOTE: For EN Grade 2 the maximum exit delay should not exceed 30s
Long Entry Delay
100 Secs
A second separate entry delay that can be used on a sensor needing more time when tripped
(45-240secs). With SIA limits disabled the minimum time can be set to 5 secs. NOTE: Not for use with
EN Grade 2.
Long Exit Delay
120 Secs
A second separate exit delay that can be used on a sensor needing more time when tripped
(45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window
group 12 follows the “Long Exit Delay”. NOTE: Not for use with EN Grade 2.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 41 173