BCR advanced license
For the BCR advanced license the following functions are available:
The basic functions (insert/accumulate, Customer ID).
Sheet sequence - Every sheet has a number, regardless of the document set it is
part of. If a sheet is missing, an error is generated.
Group sequence - Every document in a set has the same group number. If one
document set is missing, an error is generated.
Divert (Divert & Continue) - The set will be diverted and the system continues.
Stop (Divert & Stop) - The set will be diverted and the system stops indicating
error (FT1-RE1-000 Reading stop - Stop mark read).
Selective feed - If the system reads the command, an enclosure from the enclosure
feeder is added to the set. This function is printed on the last sheet of a set. It is also
possible to add an enclosure from the versaFeeder(s).
Sealing control - Determines if envelopes are sealed or not.
Present on Deck & Continue - The set leaves the system from the upper unit. The
system does not stop processing. The envelopes are not sealed.
Present on Deck & Stop - The set leaves the system from the upper unit. The system
stops. The envelopes are not sealed.
Exit selection - Determines if the envelope is transported to stacker or to the side
exit.