Example
AT+CFUN=?
+CFUN:(0,1,4,7),(0-2)
OK
AT+CFUN=1
OK
AT+CFUN?
+CFUN:1
OK
2.17. AT+CMEE Report Mobile Termination Error
The set command disables or enables the use of final result code “+CME ERROR:<err>” as an indication
of an error relating to the functionality of the MT. When enabled, MT related errors cause “+CME
ERROR:<err>” final result code instead of the regular “ERROR” final result code. “ERROR” is returned
normally when error is related to syntax, invalid parameters or TA functionality.
The read command returns the current setting of <n>.
The test command returns values supported as a compound value.
2 Do not reset MT before setting it to <fun> power level and save <fun> value in
NVRAM for all subsequent resets.
AT+CMEE Report Mobile Termination Error
Write Command
AT+CMEE=<n>
Response
TA disables or enables the use of result code +CME ERROR:
<err> as an indication of an error relating to the functionality
of the ME.
OK
Read Command
AT+CMEE?
Response
+CMEE:<n>
OK
Test Command
AT+CMEE=?
Response
+CMEE:(list of supported <n>s)