BC26_AT_Commands_Manual 42 / 73
Example
AT+CEDRXRDP
+CEDRXRDP:4,2,2,2
OK
AT+CEDRXRDP=?
OK
2.21. AT+CEER Extended Error Report
The execution command causes the TA to return one or more lines of information text <report>,
determined by the MT manufacturer, which should offer the user of the TA an extended report of the
reason for the following errors:
The failure in the last unsuccessful call setup (originating or answering) or in call modification;
The failure in the last call release;
The failure in the last unsuccessful GPRS attach or unsuccessful PDP context activation;
<Paging_time_window> String type; half a byte in a 4-bit format.
bit
4 3 2 1 Paging Time Window length
0 0 0 0 2.56 seconds
0 0 0 1 5.12 seconds
0 0 1 0 7.68 seconds
0 0 1 1 10.24 seconds
0 1 0 0 12.8 seconds
0 1 0 1 15.36 seconds
0 1 1 0 17.92 seconds
0 1 1 1 20.48 seconds
1 0 0 0 23.04 seconds
1 0 0 1 25.6 seconds
1 0 1 0 28.16 seconds
1 0 1 1 30.72 seconds
1 1 0 0 33.28 seconds
1 1 0 1 35.84 seconds
1 1 1 0 38.4 seconds
<Paging_time_window> String type; half a byte in a 4 bit format. The paging time window
refers to bit 8 to 5 of octet 3 of the extended DRX parameters
information element (see subclause 10.5.5.32 of
3GPP TS 24.008 [8]). For the coding and the value range, see the
extended DRX parameters information element in
3GPP TS 24.008 [8] Table 10.5.5.32/ 3GPP TS 24.008.