EasyManua.ls Logo

Quectel BC26 - AT+MIPLDELETE Delete OneNET Instance; AT+MIPLADDOBJ Add LWM2 M Object

Quectel BC26
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NB-IoT Module Series
BC26 AT Commands Manual
BC26_AT_Commands_Manual 64 / 73
7.2. AT+MIPLDELETE Delete OneNET Instance
The command is used to delete an OneNET communication instance.
Parameter
7.3. AT+MIPLADDOBJ Add LWM2M Object
The command is used to add LWM2M object.
Parameter
<flag> Integer. The message indication. The range is 0-2. If <flag>=1, means the first
message of the configure bin. If <flag>=2, means the middle message ofthe configure
bin. If <flag>=0, means the last message of the configure bin.
<Ref> If configure the ONENET complete, will return a <Ref: id>.
AT+MIPLDELETE Delete OneNET Instance
Write Command
AT+MIPLDELETE=<Ref>
Response
OK
If there is an error related to ME functionality:
ERROR
<Ref> Reference ID of OneNET communication instance.
AT+MIPLADDOBJ Add LWM2M Object
Execution Command
AT+MIPLADDOBJ=<Ref>,<objId>,<in
sCount>,<insBitmap>,<attrCount>,<a
ctCount>
Response
OK
If there is an error related to ME functionality:
ERROR
<Ref> Reference ID of OneNET communication instance.
<objId> Integer. Object identifier. If the object ID is not existed, the module will return ERROR.
<insCount> Integer. Instance count.
<insBitmap> Instance bitmap. For example, if <insCount>=3, and the <insBitmap>=101, means the

Table of Contents