NB-IoT Module Series
BC26 AT Commands Manual
BC26_AT_Commands_Manual 66 / 73
7.6. AT+MIPLCLOSE Send OneNET Logout Request
The command is used to send OneNET Logout Request.
Parameter
7.7. AT+MIPLREADRSP Respond the Read Request from Application
Server/IoT Platform
The command is used to respond the read request from Application Server or IoT platform.
Parameter
AT+MIPLCLOSE Send OneNET Logout Request
Write Command
AT+MIPLCLOSE=<Ref>
Response
OK
If there is an error related to ME functionality:
ERROR
<Ref> Reference ID of OneNET communication instance.
AT+MIPLREADRSP Respond the Read request from Application Server/IoT platform
Write Command
AT+MIPLREADRSP=<Ref>,<msgID>,<
objID>,<insID>,<resID>,<valuetype>,<
len>,<value>,<index>,<flag>
Response
OK
If there is an error related to ME functionality:
ERROR
<Ref> Reference ID of OneNET communication instance.
<msgID> Integer. The message identifier, which from the URC “+MIPLREAD:”
<objID> Integer. Object identifier.
<insID> Integer. The instance identifier, which from the URC “+MIPLREAD:”
<resID> Integer. The resource identifier, which from the URC “+MIPLREAD:”.
<valuetype> Integer. The value type.
1 String
2 Opaque
3 Integer