Issue 1.5 Q-Drive Installation Manual
Copyright © 1996 Quin Systems Ltd. Page 53
the motor remaining stationary, find the limits of the range and set the value
to the mid point.
Press the < F2 > key to save this value.
b) Speed compensation
The Speed factor parameter allows adjustment of the motor speed from -
6000 rpm to + 6000 rpm.
Press the <F2> key to save this value.