D9000/D7000 Series Operation & Installation Manual
Page 56
74-07692-000-C 4/97
System Chart
Household Burglary
Household Fire
Household Fire/
Burglary Combined
Central Station Burglary
(Grade C)
Police Connected
Burglary
Local Burglary
Remote Station or
Auxiliary Fire
Local Fire/Burglary
Combined
Local Fire
Local and Central Station
Fire Combined
Local and Central Station
Fire/Burglary (Grade C)
Central Station Fire/
Burglary Combined
Central Station Fire
Electrically Actuated
Transmitter
D8103 Enclosure
D8109 Enclosure
D8108A Enclosure
Minimum Hours
of Standby
Battery
4
24 +
4 mins
alarm
24 +
4 mins
alarm
4 4 4
60 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
24 +
5 mins
alarm
Choose one.
D101 lock required
for enclosure
No No No No No No No No No No
Req.
No No
Req.
Req.
No
Choose
One
Choose one.
D122 and D122L Dual
Battery Harness
Calculate current draw to determine
if second battery is required
Calculate current draw to determine
if second battery is required
Req.
D125B Powered
Loop Interface
D129 Class A
Initiating Module
Opt.
#
Opt. Opt. Opt.
#
##
# - D125 or D129 required to connect fire alarm initiating
devices to zones 1-8. D125 provides two powered loops
for connecting listed 2-wire smoke detectors. D129
provides two non-powered Class A initiating circuits.
D126 Battery 1+ 1+ 1+ 1+ 1+ 1+ 2+ 1+ 1+ 1+ 1+ 1+ 1+ 1+
D127 Reversing Relay
Opt. No Opt. NoOpt.Opt. Opt. NoOpt. Opt.No NoOpt. No
D928 Dual Phone
Line Module
Opt. Opt.
Opt. Opt. Opt.Opt.
Required for communication on two phone lines
and/or CPU watchdog function.
D161 Telephone
Cord
Required to connect panel to
RJ31X TelCo. Block
2 Req.
Two Required to connect D128
Module to RJ31X TelCo. Blocks
D185 Auxiliary
Interface Kit
*
Opt. Opt.
Opt. Opt. Opt.Opt.
Required for indicating circuits.
Opt. Opt.
Smoke Detector/Base
1++
Opt. Opt. Opt.
1+ 1+
1+ 1+
Opt.
**
1+1+, **
Opt.
1+
Opt.
D268 / D269H
Independent
Zone Control
Optional, only connect to zones 1 to 8.
Opt. Opt. Opt.
Opt.
1++
**
1+
Indicating Device
D1255 Comnd Center 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+
Opt.
Optional, may be required by job specifications and/or Authority Having Jurisdiction.
D192A/C Bell
Circuit Supervision
Opt. Opt.
Opt. Opt. Opt.Opt.
No = Not acceptable for this application
Req. = Required for this application
Opt. = Optional for this application
# = D125 or D129 required to connect fire alarm initiating devices to zones 1 to 8.
D125 provides two powered loops for connecting listed 2-wire smoke detectors.
D129 provides two non-powered Class A initiating circuits.
1+ = One or more required for this application. Consult the appropriate standard.
2+ = Two or more required for this application. Consult the appropriate standard.
1++ = At least one detector required. You can substitute other 2-wire detectors
listed for use with the D125. You could also use the D262 with the D270
four-wire base and a listed power supervision relay.
* = Auxiliary requires the D184 Auxiliary Local Energy Interface Kit.
** = Listed bell (siren) housing required for burglary alarm bell or siren.
[Empty Box] = Not used for this application.
Indicating Device
D461 Pull Station
D1640 Transformer
Required for all applications.
Opt. Opt.
Opt. Opt. Opt.Opt.
Required.
D8004 Transformer
Enclosure
D8122 Derived
Channel S.T.U.
Optional, contact TelCo. for availability of derived channel service.
D8125 POPEX Module
Required for D8127T/U and D9127T/U POPITs.
D8127T/U & D9127T/U
POPIT Modules
Opt. Opt. Opt. Opt. Opt.Opt. Opt. Opt. Opt. Opt. Opt.Opt. Opt.
D8129 OctoRelay
Optional, for remote annunciation of system functions.
D8130 Release
Module
Optional.
D8132 Battery
Charger
See Current Rating Chart and Standby Battery Requirements to determine
if system requires a D8132 Module for increased battery standby.
D9131A Parallel
Printer Interface
Optional, use with parallel printer to print events from panel log locally.
D9210B Access
Control Interface
Opt.
No Opt. Opt. Opt. Opt.Opt.
Opt.Opt.
Opt.
Opt.
No
Opt. Opt. Opt.Opt. No Opt. No Opt. Opt. No No
No
NoOpt.NoNo
D8128C OctoPOPIT
D1256
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt. Opt. Opt.
D1257
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
Opt.
www.PDF-Zoo.com