Load mass greater than high weighing threshold.
If the entered low threshold value (Min) is greater than high
threshold value (Max), <Err Lo> error is displayed.
If the entered high threshold value (Max) is greater than the
maximum capacity value, <Err Hi> error is displayed.
23. WORKING MODE - PERCENT WEIGHING
Percent weighing is a working mode enabling you to compare measured load
mass with the reference sample mass. The result is expressed in [%].
Reference sample mass can be either determined by weighing or entered
to weighing device memory by an operator.
23.1. Local Settings
To go to local settings enter <3.4.dEu> submenu.
Working mode accessibility
For detailed description read section 19.2.1.
For detailed description read section 23.1.1.
For detailed description read section 19.2.2.
For detailed description read section 19.2.3.
For detailed description read section 19.2.4.
23.1.1. Selecting Operation Mode
Parameter allowing you to select method of determination of reference weight
mass.
Procedure:
Enter <3.4.dEu / 3.4.2.UUt> submenu.
Press key, parameter values are displayed successively one by one:
Select to set reference sample mass by determining the mass value.
Select to set reference sample mass by entering the mass value.
Press key to confirm, next go to the home screen.