Airflow Requirements
The operating environment must provide airflow to the device. The required minimum airflow in
cubic feet per minute (CFM) at a temperature range of 32° to 104°F (0° to 40°C) for the APSolute
Vision platform is 20 CFM.
Optimal ambient temperature for reliable operation is 68-77°F (20-25°C).
Deviating from optimal conditions may cause temperature issues, early aging of the electronic
components and early failure of the product.
AC Power Factor
The power factor of an AC electric power system is defined as the ratio of the real power to the
apparent power, and is a number between 0 and 1.
Real power is the capacity of the circuit for performing work in a particular time. Apparent power is
the product of the current and voltage of the circuit.
The power factor for the OnDemand Switch platforms is 0.95.
Certifications Safety: CE LVD( EN 60950-1), CB - IEC 60950-1, CCC, cTUVus, AS/NZS
60950.1
EMC: CE EMC (EU directive 2004/108/EC), FCC Part 15B Class A, ICES-
003, VCCI, C-Tick
RoHS Compliant (EU directive 2011/65/EU)
Table 6: General Specifications of APSolute Vision ODS-VL2 Physical Platform
Item OnDemand Switch VL2