All equipment, antenna and external power sources must be connected to an
appropriate, regulatory-approved surge suppressor.
• The installer is responsible for verifying that the wiring AWG is rated at a suitable
amperage level for the equipment. Otherwise, the suppressor or the equipment
may be damaged by a lightning strike.
• Any connections made to pole-side cabinets must be verified to ensure that the
grounding for the ODUs also meets the requirements and local electrical earthing
regulations.
• RADWIN does not provide a warranty for equipment damaged by
electromagnetic discharge (EMD). If the guidelines provided here and local
relevant regulations are followed, the chances of damage from lightning (EMD)
can be drastically reduced.