Only use a safety-approved DC PS according to IEC/EN/UL 609501 or a 623681 with
a rated output voltage of 56VDC, 1A max.
Only use a safety-approved AC POE PS according to IEC/EN/UL 609501 or a
623681 with a rated output voltage of 2456VDC, 1A max.
All PSs must be installed in a RESTRICTED ACCESS LOCATION.
Ground the PS before applying power.
3.13 Waterproofing
This section does not apply to the RADWIN 2000 Alpha EMB ODU.
1. Protect all outdoor connections from rain, dust, moisture and salt by taping the
cable/gland connection with an appropriate sealant tape. RADWIN recommends
using Scotch™ 23 splicing tape or similar.
Figure 50 Sealant tape
2. Applying sealant tape to external connections.