Operating Manual 1302.6163.12 - 03 4.235
R&S ESU Instrument Functions
Analyzer Mode
EDIT SWEEP
LIST
Configures the sweep list.
Range Start
Start frequency of the range (relative to Center Frequency = Carrier Frequency)
Remote command: ESP:RANG1:STAR 1000000
Range Stop
Stop frequency of the range (relative to Center Frequency = Carrier Frequency)
Remote command: ESP:RANG1:STOP 10000000
Filter Type
Normal (3 dB), EMI (6 dB), Channel, RRC, 5-Pole, 5-Pole-Digital
Remote command: ESP:RANG1:FILT:TYPE RRC
•RBW
Resolution filter bandwidth
Remote command: ESP:RANG1:BAND:RES 5000
VBW
Video filter bandwidth; not applicable for Channel and RRC filters.
Remote command: ESP:RANG1:BAND:VID 5000000
TX BANDWIDTH
RRC FILT (ON OFF)
ALPHA BT
START MEAS
STOP MEAS
SWEEP LIST
RANGE 1 RANGE 2 Ref RANGE 3 RANGE 4 RANGE 5
Range Start -250 MHz -2.52 MHz 2.52 MHz
Range Stop -2.52 MHz 2.52 MHz 250 MHz
Filter Type NORMAL NORMAL NORMAL
RBW 30 kHz 30 kHz 30 kHz
VBW 10 MHz 10 MHz 10 MHz
Sweep Time Mode AUTO AUTO AUTO
Sweep Time 270 ms 10 ms 270 ms
Ref Level -10 dBm -10 dBm -10 dBm
RF Att Mode AUTO AUTO AUTO
RF Attenuator 15 dB 15 dB 15 dB
PRE AMP OFF OFF OFF
Transd Factor <NONE> <NONE> <NONE>
Limit Check ON ON ON
Limit -13 dBm -13 dBm -13 dBm
Abs Limit Start -13 dBm -13 dBm -13 dBm
Abs Limit Stop -13 dBm -13 dBm -13 dBm
Rel Limit Start -50 dBc -50 dBc -50 dBc
Rel Limit Stop -50 dBc -50 dBc -50 dBc