SPECTRUM
EMISSION
MASK
The softkey menu of the Spectrum Emission Mask measurement contains the fol-
lowing softkeys.
SPEC EM (ON
OFF)
Switches the Spectrum Emission Mask measurement on or off according to the cur-
rent configuration.
Remote command: SENS:SWE:MODE ESP
INIT:ESP
SWEEP LIST Opens a submenu to edit the sweep list and displays the SWEEP LIST dialog box.
After a preset, the sweep list contains a set of default ranges and parameters. For
each range, you can change the parameters listed below. To insert or delete ranges,
use the INS BEFORE RANGE, INS AFTER RANGE and DELETE RANGE softkeys.
SPEC EM (ON OFF)
SWEEP LIST
! EDIT SWEEP LIST
INS BEFORE RANGE
INS AFTER RANGE
DELETE RANGE
NEXT RANGES
PREVIOUS RANGES
REFERENCE RANGE
! POW REF CHAN PEAK
TX BANDWIDTH
RRC FILT (ON OFF)
ALPHA BT
START MEAS
STOP MEAS
LIST EVAL
! LIST EVAL (ON OFF)
MARGIN
LOAD STANDARD
RESTORE STANDARDS
START MEAS
STOP MEAS
EDIT SWEEP LIST
INS BEFORE RANGE
INS AFTER RANGE
DELETE RANGE
NEXT RANGES
PREVIOUS RANGES
REFERENCE RANGE
! POW REF CHAN PEAK