Operating Manual 1302.6163.12 - 03 6.121
R&S ESU Remote Control – Description of Commands
HCOPy Subsystem
HCOPy:TREPort:ITEM:DEFault
This command sets the test report configuration to a defined default status.
A newly generated test report will then contain the following:
Header line
Diagram
Scan table
Final measured values
Time of day and date
Page number
Example: ":HCOP:TREP:ITEM:DEF"
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
HCOPy:TREPort:ITEM:LOGO:CONTrol ALWays | ONCE | NEVer
In the current test report configuration, this command switches the output of the diagram on the test
instrument screen either on or off.
Example: ":HCOP:TREP:ITEM:LOGO:CONT ALW"
Characteristics: *RST value: NEVer
SCPI: device-specific
Mode: R, A
HCOPy:TREPort:ITEM:HEADer:LINE<1…7>:CONTrol ALWays | ONCE | NEVer
In the current test report configuration, this command controls whether the line indicated in the numeric
suffix of the report header is output.
The meanings are as follows:
A further condition for the output is that outputting of the report header must be switched on with ":
HCOP:TREP:ITEM:HEAD:STAT ON".
Example: ":HCOP:TREP:ITEM:HEAD:LINE2:CONT ALW"
Characteristics: *RST value: ALWays
SCPI: device-specific
Mode: R, A
HCOPy:TREPort:ITEM:HEADer:LINE<1…7>:TEXT <string>
This command defines the text used for the line of the report header indicated in the numeric suffix.
Example: ":HCOP:TREP:ITEM:HEAD:LINE2:TEXT 'radiated test'"
Characteristics: *RST value: ''
SCPI: device-specific
ALWays On each page
ONCE Only on the first page
NEVer Not on any page