R&S ESU Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
6.292 Operating Manual 1302.6163.12 - 03
R&S
ESU
FSE CALCulate<1|2>:DELTamarker<1...4>:TRACe 1 to 3 R&S ESU: 3 traces are
available per screen;
FSE: 4 traces are
available in full screen
mode and 2 traces per
screen in split screen
mode
R&S
ESU
FSE CALCulate<1|2>:DELTamarker<1...4>:X 0 to MAX (frequency |
sweep time)
unit 'SYM' is not
available for R&S ESU
R&S
ESU
FSE CALCulate<1|2>:DELTamarker<1...4>:X:RELative
R&S
ESU
FSE CALCulate<1|2>:DELTamarker<1...4>:Y?
R&S
ESU
FSE CALCulate<1|2>:DELTamarker<1...4>[:STATe] ON | OFF
R&S
ESU
FSE CALCulate<1|2>:DLINe<1|2> MIN to MAX
R&S
ESU
FSE CALCulate<1|2>:DLINe<1|2>:STATe ON | OFF
FSE CALCulate<1|2>:FEED 'XTIM:DDEM:MEAS' |
'XTIM:DDEM:REF' |
'XTIM:DDEM:ERR:MPH'
| 'XTIM:DDEM:ERR:
VECT' | 'XTIM:DDEM:
SYMB' | 'XTIM:AM' |
'XTIM:FM' | 'XTIM:PM' |
'XTIM:AMSummary' |
'XTIM:FMSummary'
|'XTIM:PMSummary' |
'TCAP'
not available for
R&S ESU
FSET CALCulate<1|2>:FEED 'XTIM:DDEM:MEAS' |
'XTIM:DDEM:REF' |
'XTIM:DDEM:ERR:MPH'
| 'XTIM:DDEM:ERR:
VECT' | 'XTIM:DDEM:
SYMB' | 'TCAP'
not available for
R&S ESU
R&S
ESU
FSE CALCulate<1|2>:FLINe<1|2> 0 to f
max
R&S
ESU
FSE CALCulate<1|2>:FLINe<1|2>:STATe ON | OFF
FSE CALCulate<1|2>:FORMat MAGNitude | PHASe |
UPHase | RIMag |
FREQuency | IEYE |
QEYE | TEYE | FEYE |
COMP | CONS
not available for
R&S ESU
FSE CALCulate<1|2>:FSK:DEViation:REFerence <numeric value> not available for
R&S ESU
FSE CALCulate<1|2>:LIMit<1...8>:ACPower:ACHannel 0 to 100 DB,
0 to 100 DB
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ACHannel [:RELative] of
R&S ESU
not available for FSET