596User Manual 1178.5966.02 ─ 20
Parameters:
<Channel> String containing the name of the channel setup.
For a list of available channel setup types use INSTrument:
LIST? on page 570.
<State> 1 | 0 | ON | OFF
1 | ON
The channel setup windows are included in the printout.
0 | OFF
The channel setup windows are not included in the printout.
*RST: 1
Example:
HCOP:CONT WIND
HCOP:PAGE:WIND2:CHAN 'IQ Analyzer',0
HCOP:PAGE:WIND2:STAT 'IQ Analyzer','1',1
Prints only window 1 in the IQ Analyzer channel setup.
Manual operation: See "Print Multiple Windows" on page 107
HCOPy:PAGE:WINDow:COUNt <Count>
This command defines how many windows are displayed on a single page of the print-
out for HCOPy:CONTent on page 590.
Parameters:
<Count> integer
*RST: 1
Example:
HCOP:PAGE:WIND2:COUN 2
Manual operation: See "Windows Per Page" on page 114
HCOPy:PAGE:WINDow:SCALe <Scale>
This command determines the scaling of the windows in the printout for HCOPy:
CONTent on page 590.
Parameters:
<Scale> 1 | 0 | ON | OFF
1 | ON
Each window is scaled to fit the page size optimally, not regard-
ing the aspect ratio of the original display. If more than one win-
dow is printed on one page (see HCOPy:PAGE:WINDow:COUNt
on page 596), each window is printed in equal size.
("Size to fit")
0 | OFF
Each window is printed as large as possible while maintaining
the aspect ratio of the original display.
("Maintain aspect ratio")
*RST:
1